UNCERTAINTY IN CALCULATING AIR EXCHANGE RATE OF NATURALLY VENTILATED DAIRY BUILDING BASED ON POINT CONCENTRATIONS
Autori: Chayan K. Saha
Data aparitiei: Septembrie / 2014
Revista: Environmental Engineering and Management JournalVol. 13Nr. 9
ISSN: 1843 - 3707
Pret: 25.00 RON    
N.A.
Abstract
Accurate quantification of gaseous emissions from livestock buildings to the atmosphere requires accurate determination of the
ventilation rate and the representative gas concentration in the exhaust air. But there is a lack in the investigation of reasons and
uncertainties for selecting sampling points and locations in naturally ventilated dairy (NVD) buildings. The objective of this
study was to investigate uncertainties in calculating AER based on carbon dioxide (CO2) balance method. The experiment was
carried out in an NVD building located in north-east Germany. Concentrations of CO2 were continuously measured inside the
barn at eight uniformly distributed points and outside the barn at four points. Air exchange rate (AER) per hour was calculated
using the concentration difference between inside and outside the barn where inside concentrations of 4 sampling locations left
(4PL), middle (4PM), right (4PR) and corner (4PC) of the barn, 6 sampling locations in left (6PL), right (6PR) and randomly
(6RS) selected points inside the barn were used, then compared with AER calculated using an average CO2 concentration of 8
sampling points (8PA) according to the CO2 balance method. The results showed that the relative AER calculation differences
using 4PL, 4PM, 4PR, 4PC, 6PL, 6PR, and 6 RS were -49 to 112%, -5 to 26%, -29 to 34%, -12 to 13%, -5 to 44%, -14 to 10%
and -8 to 4% compared to 8PA. The variations in relative differences are because of uncertainties involved in point concentration
measurement due to the variations of outside wind speed and direction.